<LOGO>
FM Transmitter Measurement Report
Created: 2026-05-09 13-16-44
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 39 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 4.9 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
15 kHz 70 kHz 7246 1,7527
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,5 dBr 4,57 dBr 5,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 70 kHz MIN: 15 kHz % above 76 kHz: 1,7527 Acquired: 2026/05/09 13.15.39 Total samples: 7246 Equivalent time: 0:06:02 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300
FM Scope MAX: 5,9 dBr MIN: 1,5 dBr AVE: 4,57 dBr % above 12,2 dBr: 0,0 Last value: 5,4 dBr (2026/05/09 13.15.39) 13.02 13.04 13.06 13.08 13.10 13.12 13.14 0 2 4 6 Pm [dBr]